Volume Control Dampers (VCD), Motorized and Backdraft Dampers, Made in Egypt
HTC manufactures air control dampers to any size in millimetres: manual volume control (VCD), motorized, backdraft, pressure relief and round dampers. Send a schedule of thirty dampers in thirty sizes and you get one offer, with a datasheet for each item.
Options
| Element | Choices |
|---|---|
| Function | Manual volume control, motorized, backdraft (gravity), pressure relief |
| Frame | Press-braked channel or hat section, roll-formed section, extruded aluminium |
| Blade | Single-skin V or 3V steel, double-skin steel airfoil, extruded aluminium airfoil |
| Blade action | Parallel or opposed |
| Seals | None, blade seals, blade and jamb seals |
| Linkage | Exposed on the blades, or concealed in the jamb |
| Bearings | Nylon/acetal, bronze, stainless steel |
| Shape | Rectangular, round (single blade or multi-blade) |
How each damper is engineered
- The number and width of blades are calculated from the height you give, within the blade width limit of the model.
- Blade deflection under the closed pressure difference is checked; a thicker blade or a split width is used when needed.
- Openings larger than one section are built as multi-section assemblies with mullions and a jackshaft.
- The actuator is selected from the face area, blade and seal type and air velocity, using the actuator maker's torque tables with a safety factor.
Stated plainly
Pressure drop and leakage are estimated values — the product is not tested to AMCA 500-D, and no AMCA seal is used. Seal classes are a design target.
Where we supply
HTC manufactures in Egypt and supplies projects in Egypt. Export to Saudi Arabia, Libya, Jordan and Iraq is planned; send your enquiry and the factory will tell you what is possible today.
Head office: 73 Othman Ibn Affan Street, El Safir Square, Heliopolis, Cairo, Egypt.
How to order
Send the damper schedule through the request form: size (W × H in mm), function, manual or motorized (voltage and control signal), air velocity and pressure if known. Excel BOQs are accepted as they are. Every request is reviewed by the factory before any reply.
Frequently asked questions
Can I order dampers in any size?
Yes. Every damper is made to the width and height you give in millimetres. Large openings are built as multi-section assemblies with mullions and a jackshaft.
Can I send a whole BOQ?
Yes. A schedule of many dampers in many sizes is processed as one request and returned as one offer, with a datasheet per item.
How is the actuator chosen?
From the damper face area, blade and seal type and air velocity, using the actuator maker's torque data with a safety factor. Large dampers are split over several actuators.
Are leakage and pressure drop tested?
No. They are estimated values; the product is not tested to AMCA 500-D, and the documents say so.
Have a project? Send the data through the request form.
Request a technical offerSources
- AMCA Publication 511-21 (Rev. 12-22), Table 4: leakage classes 1A, 1, 2 (eng_constants leakage_class, free PDF at amca.org)
- Belimo Aircontrols (USA), How to Select a Damper Actuator, T15000 - 04/18: torque loading table (eng_constants torque_loading_in_lbf_ft2, read 27 Nov 2026)
- HTC engineering spec engineering/dampers.md, section A
- AMCA 500-D — Laboratory Methods of Testing Dampers for Rating
- SMACNA HVAC Duct Construction Standards