Pressure Vessels, Expansion Tanks and Foam Bladder Tanks Made in Egypt
HTC designs and fabricates pressure tanks in Egypt up to 20,000 litres and 16 bar, calculated to ASME VIII Division 1 rules — without ASME stamp and without third-party inspection. Each tank is delivered with its calculation note, drawings and a hydrostatic test record.
Tank types
| Type | Features |
|---|---|
| Foam bladder tank | Vertical or horizontal, internal bladder, perforated centre pipe, water and foam connections |
| Expansion and pressurization tank | Usually vertical, bladder or diaphragm, pre-charged air |
| Surge vessel (water hammer) | Bladder, large bottom connection |
| Hydropneumatic tank | No bladder, air cushion, sight glass and compressor connections |
How each tank is calculated
- Volume from the application: foam concentrate quantity (NFPA 11), expansion volume (ASHRAE), pump drawdown, or a preliminary surge estimate.
- Shell and heads from ASME VIII-1 (UG-27, UG-32), with corrosion allowance and the next available plate thickness; MAWP is calculated back from the actual thicknesses.
- Economic comparison: SA-516 Gr. 70 against SA-36 where the code allows it, and joint efficiency with full, spot or no radiography — the cheapest compliant combination is shown next to the standard one.
- Supports: saddles for horizontal tanks, legs or skirt for vertical ones, checked full of water.
- Hydrostatic test per UG-99(b), recorded with pressure, holding time and gauge calibration.
The tank file
Calculation note with the engineer's signature box, general arrangement and part drawings with DXF, bill of materials with required mill test certificates, weld map, inspection and test plan, hydrostatic test record, nameplate data, and bladder installation and pre-charge instructions.
Stated plainly
- Designed and fabricated to ASME VIII Div. 1 rules — without ASME stamp and without third-party inspection.
- The code requires qualified welding procedures and welders (Section IX); the file records their numbers, or shows them as missing.
- Foam tanks do not carry UL 162 or FM 5130 approval.
Where we supply
HTC manufactures in Egypt and supplies projects in Egypt. Export to Saudi Arabia, Libya, Jordan and Iraq is planned; send your enquiry and the factory will tell you what is possible today.
Head office: 73 Othman Ibn Affan Street, El Safir Square, Heliopolis, Cairo, Egypt.
How to order
Send the tank data through the request form: type, volume or system data, design pressure and temperature, vertical or horizontal, connections. Every request is reviewed by the factory before any reply.
Frequently asked questions
Do HTC tanks carry an ASME stamp?
No. They are designed and fabricated to ASME VIII Div. 1 rules, without ASME stamp and without third-party inspection. Every calculation note says so and has a signature box for the responsible engineer's review and approval.
What sizes and pressures can you build?
Up to 20,000 litres and 16 bar, vertical or horizontal, with or without a bladder.
Which documents come with a tank?
Calculation note, general arrangement and part drawings, material requirements with mill test certificates, weld map, inspection and test plan, hydrostatic test record and nameplate data.
Are foam bladder tanks UL or FM approved?
No. Where a project requires UL 162 or FM 5130, the documents state that the tank does not carry that approval.
Have a project? Send the data through the request form.
Request a technical offerSources
- ASME Continuing Education course notes, ASME B&PV Code Section VIII Division 1: Design and Fabrication of Pressure Vessels (2001, 1998 edition), in the U.S. NRC ADAMS library (ML040150682): UG-27 shell and UG-32 head formulas, read 28 Nov 2026
- Oak Ridge National Laboratory report ORNL/SPR-2022/2425 (ASME VIII-1, 2021 edition) and 46 CFR 54.10-10(b): hydrostatic test at 1.3 times MAWP times the lowest stress ratio, read 28 Nov 2026
- ASME BPVC Section VIII Division 1; Section II Part D
- NFPA 11 — foam systems
- ASHRAE Handbook — hydronic systems
- HTC engineering spec engineering/tanks.md